Following is what will be written in case if you choose to use /codebase option while registering.Its advisable to use /codebase command line switch when you dont have your assembly in GAC because that will add absolute path for your assembly in registry so that COM client (your native application which uses.This checks the ProgId and Type and register it as Office Addin (creates the necesary Registry Entries). NET doing this (like regasm.exe)) wich calls ADXRegister. It registers your AddIn Assembly (there is a Service of. If you put your assembly in GAC, you don't have to use /codebase command line switch with regasm, because application will be able to find the assembly using default probing mechanisms. It creates a TypeLib of ADX, registers both the TypeLib and ADX Assembly and places the Assembly into the GAC.There are two options while registering the assembly for COM Interop,
![how to register assembly with regasm using installshield how to register assembly with regasm using installshield](https://3.bp.blogspot.com/-FQeEPt6oGXM/TYdySFGtvoI/AAAAAAAAADU/C5weTqSmlAs/s1600/4-VisualStudioCommandPrompt.png)
(Basically what it does is, it calls regasm after DLL is built!) If you are developing project in Visual Studio, there is option to register your assembly with COM Interop in Project Properties (Right click on project and choose properties), Go to Build tab, There is an option for "Register for COM Interop". More on regasm and its command line options is described here.
#HOW TO REGISTER ASSEMBLY WITH REGASM USING INSTALLSHIELD 64 BIT#
NET framework installed, you should find 32bit version of regasm in,Ĭ:\windows\\ Framework\v7\regasm.exeĪnd 64 bit version of regasm should be in,Ĭ:\windows\\ Framework64\v7\regasm.exe NET Framework 2.0 installed, regasm would be in following path (assuming you have 32-bit OS)Ĭ:\windows\\Framework\v7\regasm.exe To get an assembly registered on system, you can use regasm utility that comes with. Symptoms These error message relates to the Enterprise Single Sign-On Service, and may produce one of the following error codes: Windows could not start the Enterprise Single Sign-On Service. As per COM rules, you need to get your assembly registered on system (in Registry, yes, thats how COM works!). NET DLL (assembly) from VB6 or C++ application (native code) ? Yes, you can do that using COM Interop.
![how to register assembly with regasm using installshield how to register assembly with regasm using installshield](http://lh4.ggpht.com/_En4lyuSsx2g/SzZabO9llDI/AAAAAAAAAHY/vJOvyakQryA/image_thumb[3].png)
NET Assembly for COM Interop ?ĭo you want to use your.